What needs to be done in the maintenance phase of axial fan

Source: Time:2020-09-28 14:13:46 views:

Axial-flow low-noise fans, like other types of fans, need to be maintained during use, so as to better allow the axial-flow fan to perform its due role and extend the service life of the fan. Maintenance work has always been a concern of users. What needs to be done during the maintenance phase of axial flow fans?
Axial-flow low-noise fans, like other types of fans, need to be maintained during use, so as to better allow the axial-flow fan to perform its due role and extend the service life of the fan. Maintenance work has always been a concern of users. What needs to be done during the maintenance phase of axial flow fans?
1. What needs to be done is that the axial flow fan needs to be pressed to keep the air duct unblocked during operation. The axial flow fan will be overloaded when the air volume is very small. Be careful not to use it for a long time in a sealed and insufficient air supply environment or when the valve is fully closed. In the best case, the current should be regularly monitored.
2. Before the axial fan is used, the fan must be tested. This process is to ensure the fan's operation without failure, so that the effectiveness of the fan is guaranteed to the greatest extent.
3. If the fan has not been used for a long time and is used again, you must first check whether the various parts of the fan are still firm. Once you find any looseness, you must tighten it in time, so that during the test operation of the fan , The fan cannot be used normally due to the loosening of fan components.
4. Before starting the fan, it is necessary to check whether there are any objects in the fan and pipes that impede the rotation. If any, it should be cleared before starting.
5. After the fan is debugged and no problem is found, it should be put into use cautiously, and every reflection of the fan should be observed regularly. Once an abnormality is found, it should be shut down immediately for inspection.
6. The components of the fan should be checked regularly to ensure that the fan can start at any time and run normally. Do not use the fan too frequently to start and stop the fan, otherwise it will easily cause the motor to burn out.
7. In order to avoid damage to the fan blades due to damage to the dynamic balance of the fan blades, resulting in increased vibration and damage to the fan, the fan blades must be inspected regularly every month.